DCA Error Codes

ConnectEMC Event Alerts

The table below lists all the conditions that cause ConnectEMC to send event data alerts to EMC Global Services.

The gadget spec URL could not be found


DCA Error Codes
 Code Description
 1.1  Host not responding to SNMP calls, host may be down.
 1.4  Interface status: could not open session to host 1.
 2.15 Greenplum Database is ready to accept connections. 
 2.15005 Greenplum Database panic, insufficient resource queues available.
 3.2000 Status of power supply, if PS fails, will get error with this code.
 4.3000 Status of battery on system. Will report error on failure.
5.4001 Status of cooling device, e.g. fan failure. 
 5.4002 Temperature of system.
 6.5001 Status check of a CPU. CPU failure will register here.
 7.6001 Status of a CPU Cache device. Cache device failure will register here.
 8.1002 Operating System Memory Status.
 9.7000 Memory device status. Failed memory devices will get this code.
 10.8003 Status of the network device.
 10.8005 A configured network bond is unavailable.
 10.8006Network bonding on master servers: The bond interface has no active link/slave. 
 10.8007 Network bonding on master servers: The bond interface link/slave has changed.
 10.8008 Network bonding on master servers: The bond interface links are all down.
 10.8009 Network bonding on master servers: One of the bond interface links is down.
 11.9001  Status of IO Controller.
 11.9002  Status of battery on the IO Controller.
 12.10002  Virtual Disk 1 Status: /dev/sda: nonCritical.
 12.10004  Virtual disk size (MB).
 12.10005 Write cache policy on virtual disk. For example, expected to be write back mode.
 12.10006 Read cache policy of virtual disk. For example, expected to be adaptive read ahead.
 12.10007 Detects offline, rebuilding raid and other unexpected virtual disk states.
 12.10011  Percentage of disk space on virtual disk used.
 12.10012 Virtual disk space used (KB).
 13.11001  Status of drive. Drive failures use this ID.
 14.12002  Interconnect Switch Operational Status.
 14.12005 Operational status of Interconnect switch flash memory.
 14.12006  State of Interconnect switch flash memory.
 14.13001  Status errors from switch sensors - Fans, Power Supplies, and Temperature.
 14.14  Interface 0 Description: unexpected snmp value: val_len<=0. 
 14.14001 Interface 0 Status: unexpected status from device.
 15.2  An error detected in the SNMP configuration of the host.
 15.3  Other SNMP related errors.
 15.4 Connection aborted by SNMP.
 15.5  Unexpected SNMP errors from the SNMP system libraries.
 15.6  Can not find expected OID during SNMP walk.
 16.0  Test Dial Home.
 18.15000  Sent from inside GPDB when starting up.
 18.15001 Sent from inside GPDB when GPDB could not access the status of a transaction.
 18.15002 Sent from inside GPDB when interrupted in recovery.
 18.15003  Sent from inside GPDB when a 2 phase file is corrupted.
 18.15004 A test message sent from inside GPDB.
 18.15005  Sent from inside GPDB when hitting a panic.
 18.17000  Sent by healthmond when GPDB status is normal.
 18.17001 Sent by healthmond when GPDB can not be connected to and was not shutdown cleanly, possible GPDB failure.
 18.17002 Sent by healthmond when detecting a failed segment.
 18.17003 Sent by healthmond when detecting a segment in change tracking.
 18.17004  Sent by healthmond when detecting a segment in resync mode.
 18.17005 Sent by healthmond when detecting a segment not in its preferred role, unbalanced cluster.
 18.17006  Sent by healthmond when detecting a move of the master segment from mdw to smdw.
 18.17007 Sent by healthmond when detecting a move of the master segment from smdw to mdw.
 18.17008 Sent by healthmond when a query fails during health checking.
 18.17009 Healthmond error querying GPDB State.
 19.18000 ID for informational dial homes with general system usage information.
 21.20000  Core files were found on the system.
 21.20001  Linux kernel core dump files were found on the system - indicates a crash and reboot.
 22.21000 Master Node Failover was successful.
 22.21001  GPActivatestandby command failed during master node failover.
 22.21002  Greenplum Database is not reachable after the failover.
 22.21003 Error in bringing the remote(other) master server down during master node failover.
 22.21004  Error in taking over the remote(other) master server IP.
 22.21005  Unknown error in failover.
 23.22002 Host did not complete upgrade within the specified timeout period. Timeout period is 12 hours by default unless set in /opt/dca/etc/healthmond/healthmond.cnf.

 



The gadget spec URL could not be found


The gadget spec URL could not be found


Comments